Service Details
- Home
- Service Details
For electrical appliance inspections, or household appliance preshipment inspection, the general inspection procedure will be:
Onsite Quality Inspection checkpoints for appliances:
CHECK LIST | COMMENTS | RESULT |
---|---|---|
Perform a strength check.-Test all connections using normal force.-II | PASSED | |
Perform a voltage range test -II | PASSED | |
Perform a life test. Continue to run this test during the whole inspection period. ----S1 (5 Pcs) | PASSED | |
perform quantity and assortment check in each package--S3 | FAILED | |
Perform an internal check.-Take all related pictures to show special requirements. ----S1 (5 Pcs) | PASSED | |
Check if the base of the item wobbles by placing it on a flat, glass surface--II | PASSED | |
Perform UPC Barcode scan check | PASSED | |
Smell check-check if there are any strong offensive odor-II | PASSED | |
Perform a rub test for printing and marking ; Adhesive test for coating if applicable-For rub test: The durability of the marking is checked by trying to remove it by rubbing lightly for 15 s with a piece of cloth soaked with water and, after drying, for a further 15 s with a piece of cloth soaked with petroleum spirit; if the spirit not available, use the 95% alcohol - After the test, the marking shall be legible, marking labels shall not be easily removable and they shall show no curling. | FAILED | |
Perform a Hi-pot testing -II | N/A | |
Run the test work for 4 hour ----S2 | PASSED | |
Perform an assembly check.--II | PASSED | |
Function test : ----II | N/A | |
Check all the accessories with the item.--S2 | N/A | |
Perform a fatigue test on all adjustable parts.--S2 | PASSED | |
Perform the standard power test-II | PASSED | |
Perform a carton drop test on the export cartons: 10 times (1 corner 3 edges 6 faces) | PASSED | |
Perform a humidity test on solid wood and MDF parts with wood humidity tester (brand name: Testo), Please fill the detail finding table for wood humidity test. The sample should be taken: - On S3; - In at least 10 different cartons - Provide at least 1 picture for each measurement point position (to show where the test was done = 3 pictures totally) -Check the humidity for wood: check 3 points(a, b and c) per unit- For wooden items, the humidity tolerance for April to October: 12% Max -II | FAILED | |
Leakage current test----II | PASSED |
This inspection will help the buyers verify the final product quality level, find unexpected risks, and collect info for further continuous improvements;
For most appliance inspections, we offer:
China appliance factory inspection, China appliance factory inspection services, China appliance 3rd party factory inspection services, appliance 3rd party factory inspection in China, China appliance 3rd party factory inspection, China appliance third party factory inspection, appliance 3rd party factory inspection, appliance factory inspection in China, appliance 3rd party factory inspection services in China, appliance factory inspection services, China appliance third party factory inspection services,