Service Details

  • Home
  • Service Details

Shunde QC check:


Shunde is in Foshan city Guangdong province China, well known for its manufacturers of electrical appliances and furniture. It has many very famous home appliance makers in the world.

The Shunde third party inspections will check the product quality as per below inspection list:

  • A. Quantity verify
  • B. Shipping marks & packing
  • C. Labels, logos and colors
  • D. Styles & measurements
  • E. Onsite safety and function tests
  • F. Special requirements
  • G. AQL workmanship
    (Visual defects)

The inspection services in Shunde we have are mostly as follows:

Shunde QC check

Please find below for a Shunde appliance quality inspection lists for reference:

ON-SITE INSPECTION LIST COMMENTS RESULT
Leakage current test----II FAILED
Perform a voltage range test -II PASSED
Perform an assembly check.--II PASSED
Perform a carton drop test on the export cartons: 10 times (1 corner 3 edges 6 faces) PASSED
Function test : ----II PASSED
Perform a strength check.-Test all connections using normal force.-II PASSED
Perform an internal check.-Take all related pictures to show special requirements. ----S1 (5 Pcs) N/A
Run the test work for 4 hour ----S2 FAILED
Perform a fatigue test on all adjustable parts.--S2 PASSED
Perform a life test. Continue to run this test during the whole inspection period. ----S1 (5 Pcs) PASSED
Perform a Hi-pot testing -II PASSED
Smell check-check if there are any strong offensive odor-II PASSED
Perform a rub test for printing and marking ; Adhesive test for coating if applicable-For rub test: The durability of the marking is checked by trying to remove it by rubbing lightly for 15 s with a piece of cloth soaked with water and, after drying, for a further 15 s with a piece of cloth soaked with petroleum spirit; if the spirit not available, use the 95% alcohol - After the test, the marking shall be legible, marking labels shall not be easily removable and they shall show no curling. PASSED
Check if the base of the item wobbles by placing it on a flat, glass surface--II PASSED
Perform the standard power test-II N/A
Check all the accessories with the item.--S2 PASSED
Perform UPC Barcode scan check FAILED
Perform a humidity test on solid wood and MDF parts with wood humidity tester (brand name: Testo), Please fill the detail finding table for wood humidity test. The sample should be taken:
- On S3;
- In at least 10 different cartons
- Provide at least 1 picture for each measurement point position (to show where the test was done = 3 pictures totally)
-Check the humidity for wood: check 3 points(a, b and c) per unit- For wooden items, the humidity tolerance for April to October: 12% Max -II
FAILED
perform quantity and assortment check in each package--S3 PASSED

3rd party preshipment products goods factory onsite inline final Random AQL PSI TPI FRI DUPRO third party on-site in-line pre-shipment QA quality control assurance inspection services in China India Vietnam Thailand Malaysia Bangladesh Taiwan.

 

Menu