Service Details
- Home
- Service Details
How to inspect freezers? we normally check according to below checklist for freezers, mini freezer, coolers, heaters etcs.
Below is a sample checklist for mini freezer inspections:
CHECK LIST | COMMENTS | RESULT |
---|---|---|
Perform a rub test and an adhesive test-Perform the rub test and adhesive test on any and all printing found on the item-S2 | Checked on 5pcs per style. | PASSED |
3.1.- Check Packaging according files results of the tests | Conformed to artwork of gift box. | PASSED |
3.2.- Rating Labels according to attached file | Conformed to updated specification provided by client. | PASSED |
3.3.-Portuguese Instruction Manual according to attached file | Same manual was used for 2 styles, and it was same as attached file. | PASSED |
3.4.- Check if products are working (56 units for 127 V and 24 units for 220 V ) | Heating for 10min, then cooling for 10min, found the inner temperature were changed accordingly. | PASSED |
3.5.- Check if all button options are working | Press each button, conformed to intended function. | PASSED |
3.6.- Check if all components and accessories are inserted | By visual check, found conformed. | PASSED |
3.7.- Check if the products have not rust, risks, dusty etc. | By visual check, found conformed. | PASSED |
3.8.- Operate 2 units (version 127 V) for six hours ( cold temperature) verify the internal temperature take note of temperature each hour and temperature ambient also one with Dc 12 V other with 127V 60 Hz | Turn on the fridge, temperature was set to 2℃, then verify the internal temperature each hour. | PASSED |
3.9.- Operate 2 units (version 127 V) for six hours ( Hot temperature) verify the internal temperature take note of temperature each hour and temperature ambient also one with Dc 12 V other with 127V 60 Hz | each hour. Turn on the fridge, temperature was set to 60℃, then verify the internal temperature | PASSED |
3.10.- Operate 2 units (version 220 V) for six hours ( cold temperature) verify the internal temperaturetake note of temperature each hour and temperature ambient also one with Dc 12 V other with 220V 60 Hz | Turn on the fridge, temperature was set to 2℃, then verify the internal temperature each hour. | |
3.11.- Operate 2 units (version 220 V) for six hours ( Hot temperature) verify the internal temperaturetake note of temperature each hour and temperature ambient also one with Dc 12 V other with 220V 60 Hz | PASSED | |
3.12– The goods of the tests 3.12/3.13 and 3.14 should be differents samples , Dont use the same sample to do two or three tests , please send date list of the results of the tests | On all samples, found result of the tests were passed. | PASSED |
3.13.- Power cord with INMETRO certification (attached) | Refer to part 2. | PASSED |
3.14.- Inform the diameter of the plugs i n 127V and 220V and check if the p ins of the plug sho uld not be ferrous (se e wi th a magnet) the magnet not attract the pins. | 127V: 3.97mm; 220V: 3.95mm. | PASSED |
3.15.- C heck gross weigh t and n et w eight information w ith th e pack aging an d t ax document of t he all lot (t he v alues printed should be real to avoid problems with government import de partments) | Actual finding | |
3.16.- Measuring the product and accessories (L x W x H)cm | Overall size of fridge, length of AC cable and DC cable were checked, pls. refer to part 2 for details. | Actual finding |
3rd party preshipment products goods factory onsite inline final Random AQL PSI TPI FRI DUPRO third party on-site in-line QA QC check quality control assurance services in China India Vietnam Thailand Malaysia Bangladesh Taiwan.